Addtional steps for PcLaw Mobility Installation
Issue:
After doing the PcLaw mobility installation the common API is not starting nor connecting to Pclaw
Solution:
PcLaw install article: http://support.lexis-nexis.com/pclaw11/record.asp?ArticleID=10602
After serveral hours on the phone with PcLaw here are the following notes for a successful conneciton:
- Data files for logs are C:\ProgramData\LexisNexis (or all users appdata)
- Local Config file: C:\Program Files (x86)\LexisNexis\PCLaw\LOCALDATA\PCLaw.cfg. - Change the book path to the local HDD on the server instead of the UNC. Also can # out the additional books beyond 2 if there are multiple books in the signon selection.
- D:\Apps\PCLAW\DATA\Statdata\docpath.ini - Use the UNC path to the server. This is used for all workstations so it must be a server path and not local path
When starting the services, they must be started in order.
1. PCLaw Link
2. PCLaw Log
3. LexisNexis Practice Management Common API
4. LexisNexis Discovery Service
5. LexisNexis Practice Management Mobility Data Service
Please make sure that the Startup Type is set to Automatic and not Automatic (Delayed Start).